We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more
IG L1/HD 100 WIL Cavity Lintels (Heavy Duty)

Heavy Duty load wide inner leaf, for cavity widths 90-105mm to accept inner block width of 125-150mm
For 150mm Wide inner leaf blockwork.
Lintels may be propped to facilitate speed of construction. Inner leaf block should not overhang the lintel flange by more than 25mm. Blockwork built tight against inner face of the lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load.
Manufactured length 150mm increments | 600-1350 | 1500-1800 | 1950-2100 | 2250-2700 |
Height h | 113 | 144 | 165 | 188 |
Thickness | 2.9 | 2.9 | 2.9 | 3.2 |
Total UDL kN 3:1 | 20 | 35 | 30 | 36 |
Total UDL kN 19:1 | 17 | 27 | 25 | 32 |