IG I BEAM (3C) Lintels

Solid Wall lintels Extra Heavy Duty load. Suitable for 215mm solid walls.When using I Beam normal building practice should be observed in that one course and the mortar allowed to cure for at least 24 hours before additional loads are applied. Not suitable for floor loads.
Manufactured length 150mm increments | 600-1800 | 1950-2100 | 2250-3000 | 3150-4050 | 4200-4800 |
Height h | 227 | 227 | 227 | 227 | 227 |
Thickness | 2.5 | 2.5 | 2.9 | 3.2 | 3.2 |
Total UDL kN | 45 | 40 | 40 | 40 | 35 |
To discuss your IG I BEAM (3C) Lintels requirements, please email our sales team or call our sales team on 020 8254 0066.