IG L5/130 WIL Lintel

IG L5/130 WIL Lintel

For cavity widths 130-145mm, Wide Inner Leaf Extra Heavy Duty Load L5 Lintel manufactured length in 150mm increments.

To achieve loading figures lintel must be built in with blockwork as shown. Ensure all perpendicular and horizontal joints are filled with mortar. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Lintels may be propped to facilitate speed of construction.


Manufactured Length 150mm increments 600-1500 1650-2100 2250-3000 3150-4050 4200-4800
Height h 229 229 229 229 229
Thickness 2.9 2.9 2.9 3.2 3.2
Total UDL kN 19:1 70 60 50 45 40